Xw60ls Manual | Dixell

| i1P | Function | |-------|-----------| | oP | Door switch – normal open | | cL | Door switch – normal closed | | EAL | External alarm (generic) | | bAL | Serious alarm (compressor stop) | | PAL | Pressure switch alarm | | dor | Door switch with fan cut-off and defrost inhibition |

Unlike simpler thermostats, the XW60LS combines temperature control, defrost scheduling, alarm management, and compressor protection into a single DIN-rail or panel-mounted device. | Parameter | Details | |-----------|---------| | Power Supply | 230VAC ±10% or 115VAC (depending on model suffix) | | Power Consumption | 3 VA max | | Display | 3-digit red LED, 0.56” height | | Inputs | 1 x NTC/PTC probe (PTC: 1KΩ, NTC: 10KΩ at 25°C) | | Digital Input | 1 x free voltage contact (configurable) | | Relay Outputs | Compressor (8A resistive), Defrost (8A), Fan (5A) | | Operating Temp | 0° to 55°C (32° to 131°F) | | Storage Temp | -20° to 70°C (-4° to 158°F) | | Enclosure | IP20 (front panel IP65) | | Dimensions | 74 x 32 x 59 mm (front panel: 74x32mm) | Physical Layout & Terminal Connections The XW60LS features a front membrane keypad with 4 buttons and a 3-digit display. Below is the terminal block assignment (typical for XW60LS): dixell xw60ls manual

If configured as dor (door switch): opening the door stops fans and displays dA after a delay (parameter doA ). Closing the door restarts normal operation. The XW60LS flashes an alarm code on the display while the red LED blinks. | i1P | Function | |-------|-----------| | oP

For specific OEM variations (e.g., XW60LS with different probe curves or custom passwords), consult the original equipment manufacturer’s supplement. Refer to Emerson/Copeland’s official XW60LS – ISTR 03/11 installation manual or contact technical support with the controller’s full model code and firmware version (visible during power-up). Closing the door restarts normal operation

For : | Parameter | Value | |-----------|-------| | Set | -18°C | | Hy | 2°C | | LS | -30°C | | US | -10°C | | dtE | 15°C | | MdF | 30 minutes | | idF | 8 hours | Conclusion The Dixell XW60LS is a reliable, flexible controller for commercial refrigeration. Mastering its parameter structure, wiring, and alarm handling allows technicians to optimize energy efficiency, protect compressors, and maintain precise temperature control. Always keep a copy of the official parameter list and use the Hot Key for rapid deployment across multiple units.

| Parameter | Value | |-----------|-------| | Set | 2°C | | Hy | 4°C (cut-in at 4°C, cut-out at 2°C) | | LS | -5°C | | US | 8°C | | tyP | 0 (electric) | | dtE | 8°C | | idF | 6 hours | | MdF | 20 minutes | | Fnc | 2 (fan with compressor, off during defrost) | | AC | 5 min |

Introduction The Dixell XW60LS is a sophisticated microprocessor-based electronic controller designed primarily for medium and low temperature refrigerating units . Manufactured by Emerson’s Dixell division (now part of Copeland), this controller is widely used in commercial refrigeration, cold rooms, industrial freezers, and HVAC applications. It is known for its robust input/output configuration, hot key programming capability, and advanced defrost management.