Scrubber Design Calculation Excel Apr 2026
Then total ΔP = ΔP per m × Z. Minimum L/G for proper wetting: L' > 2.5 kg/m²·s (typically). If too low, increase Q_l.
= Height of transfer unit HTU = G' / (K_ya * P * MW_air) – but K_ya is empirical. Common shortcut (Onda correlation, can be coded in Excel with ~20 lines). scrubber design calculation excel
= Number of transfer units NTU = ln[(y_in - y_eq)/(y_out - y_eq)] (if linear equilibrium & dilute) Where y_out = y_in * (1 - η/100) Then total ΔP = ΔP per m × Z